Free audio tools for musicians and engineers, with the method behind every number written down.

What this site is

Station Audio is a small set of tools for the practice room and the studio: an EQ ear trainer, two tools that make sound (a tone generator and a metronome), one that listens to your hands (a tap tempo counter), and five calculators for the arithmetic that comes up while recording, mixing and setting up rooms. There is no account, no subscription and nothing to install.

How the tools work

Every tool runs entirely in your browser. The calculators are plain arithmetic in JavaScript; the EQ trainer, tone generator and metronome use the Web Audio API, which is built into current browsers and generates sound on your device. Nothing you enter is transmitted or stored, and no tool on this site uses your microphone or camera. The one thing kept between visits is the EQ trainer's own score, in your browser's local storage; see the privacy page for the details.

Every tool page shows a correct result for its default settings even with JavaScript turned off, names the formula it uses, works through an example, and says where the result stops being trustworthy. The methods are collected below so they can be checked in one place.

EQ ear trainer

Pink noise (white noise through Paul Kellet's −3 dB/octave filter) or a two-bar loop synthesised from oscillators and noise at 96 BPM, all normalised to −18 dBFS RMS, passes through one Web Audio BiquadFilterNode of type peaking (the Audio EQ Cookbook peaking filter). Band centres are the ISO 266 preferred frequencies; octave bands use Q = √2 and third-octave bands Q ≈ 4.32, from Q = √(2N) / (2N − 1). "Flat" is the same filter at 0 dB. The EQ version is turned down by its estimated loudness gain: the filter's power response integrated over 20 Hz–20 kHz on a log axis, weighted by the source spectrum (flat per octave for pink noise, falling 2–3 dB per octave for the loops) and an approximation of ITU-R BS.1770 K-weighting. A compressor at −6 dBFS with a 20:1 ratio limits peaks. A level is passed with 8 of the last 10 answers right. Limits: small speakers cannot reproduce the bottom three octaves; hearing above 12–16 kHz varies with age; the loudness match is an estimate, closer on noise than on the loops; and it trains recognition on test material, which is a step towards, not the same as, hearing EQ in a mix.

Tone generator

An OscillatorNode produces sine, square, sawtooth or triangle waves; a gain stage sets the level in dBFS, converted with gain = 10dB/20, with short fades on start and stop to avoid clicks. The frequency slider is logarithmic between 20 Hz and 20 kHz. Sweeps are exponential, so every octave takes the same time. The harmonic table is the ideal Fourier series of each waveform (odd harmonics at 1/n for a square, all at 1/n for a sawtooth, odd at 1/n² for a triangle). Limits: the browser's waveforms are band-limited, the sound you hear depends on your speakers or headphones and any processing your device applies, and the page cannot know how loud the result is in the room. It is not a hearing test or a medical device.

Metronome

Clicks are scheduled with the lookahead technique: a timer runs every 25 ms and books every click falling in the next 100 ms (1.5 s while the tab is hidden) on the audio clock, at intervals of 60 / (BPM × subdivision) seconds. Accent groupings are fixed per time signature: 4/4 as 2+2, 5/4 as 3+2, 6/8 as 3+3, 7/8 as 2+2+3, 9/8 and 12/8 in threes. Tempo terms use the ranges traditionally printed on mechanical metronomes, which vary between sources. Limits: Bluetooth audio delays every click; a sleeping phone stops the sound; other groupings of 5/4 and 7/8 exist and are not offered.

Tap tempo

BPM is 60,000 / interval, where the interval is the slope of an ordinary least-squares line through tap number against tap time, using the last 16 taps. The simple average interval and the standard deviation of the intervals are shown alongside. The count resets after a 2-second pause. Limits: it measures your tapping, not the recording, and cannot resolve music without a steady tempo. It does not listen to audio.

Delay and reverb time calculator

A quarter note lasts 60,000 / BPM ms; other note values scale from it, dotted notes are ×1.5 and triplets ×2/3, and LFO rates are 1000 / ms Hz. The reverb table applies a common mixing convention (pre-delay plus decay equals a musical length, pre-delay a short note value), presented as a starting point, not a rule. Limits: assumes the beat is a quarter note; hardware that rounds to whole milliseconds drifts slightly over long feedback trails.

Note frequency calculator

Twelve-tone equal temperament with MIDI numbering: f = A4 × 2(n − 69)/12, cents = 1200 × log2(f / fnote), octaves in scientific pitch notation (middle C = C4), and wavelength = 343 / f m. The reference pitch is adjustable; 440 Hz is the ISO 16 standard. Limits: equal temperament only; stretch-tuned pianos and just-intoned ensembles depart from these values by design.

Decibel calculator

Unrelated sources add as 10 × log10(Σ 10L/10); identical in-phase signals as 20 × log10(Σ 10L/20), shown as the upper limit. Power ratios use 10 log and voltage or pressure ratios 20 log. Distance uses the free-field inverse-square law, −20 × log10(r2/r1). Exposure times follow the NIOSH recommended exposure limit (85 dBA for 8 hours, 3 dB exchange rate) and the OSHA permissible exposure limit (90 dBA for 8 hours, 5 dB exchange rate). Limits: levels must share a weighting; the distance rule fails indoors once reverberation dominates; exposure limits are workplace criteria, not personal medical advice.

Audio file size calculator

Uncompressed size is sample rate × bit depth × channels / 8 × seconds plus a 44-byte WAV header; constant-bitrate size is kbps × 1000 / 8 × seconds. Both decimal (MB) and binary (MiB) units are shown. The WAV limit follows from RIFF's 32-bit size field. Limits: lossless (FLAC, ALAC) and variable-bitrate sizes depend on the audio and are not estimated; metadata chunks and artwork add a little.

Room mode calculator

The rectangular-room mode equation f = (c/2) √((nL/L)² + (nW/W)² + (nH/H)²) with c = 343 m/s, classified as axial, tangential or oblique. The Schroeder frequency is estimated as 2000 √(RT60 / V). Proportions are checked against the ITU-R BS.1116 listening-room criterion and compared with published ratios (Sepmeyer, Louden, golden ratio). The coincidence (within 5 Hz) and gap (over 20 Hz) flags are this site's screening heuristic, not a standard. Limits: assumes rigid walls and a rectangular, empty room; real modes are shifted and damped by construction, furnishings and openings.

Corrections

If something here is wrong, it should be fixed. Every method is stated so it can be checked against the source or worked by hand; if you find a result that disagrees with a careful hand calculation, that is a bug.